Skip to content

VBat conductor shorted to ground on PCB #14

@schofiel

Description

@schofiel

The VBat conductor between the Sparkfun TOL 10617 battery positive pin and the BAT/BAT 2 inputs to the MAX8903A charge management IC U2 (pins 21 & 20) is shorted to ground on the PCB by a flood-filled polygon zone. This is on the top copper layer. The design rule checker does not mark the intersection of the polygon with the track as a problem.

The net result is that U2 (MAX8903A) fails to regulate properly and the board fails to operate (dead short/no voltage). With the battery pack connected, the pack delivers peak current (3x 5A) to ground, with the associated fire risk due to battery failure.

An image of the polygon:

VBat Polygon

An image of the resulting top copper gerber:

VBat Polygon on Gerber

The work-around is a careful scalpel cut along the edge of the track to separate the polygon from ground.

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions