Skip to content

Conversation

danrosen25
Copy link
Collaborator

TYPE: bug fix

KEYWORDS: ZSOIL8, HYDRO_nlist, config

SOURCE: @danrosen25 NCAR

DESCRIPTION OF CHANGES: This fixes an issue where the user cannot specify the soil depths (a.k.a. soil layer thickness) in configuration files during coupled runs. If the sys_cpl type does not equal 1 the initialization routine will read ZSOIL8 from the HYDRO_nlist namelist in the hydro.namelist file. This may is not fully backwards compatible because previous coupling applications may have relied on hardcoded soil depths.

ISSUE: #571

TESTS CONDUCTED: I tested using sys_cpl=2 in a coupled LIS-WRFHYDRO application using NUOPC infrastructure.

Checklist

  • Closes issue NSOIL8 not read properly when running sys_cpl != 1 #571
  • Tests added (unit tests and/or regression/integration tests)
  • Backwards compatible
  • Requires new files? If so, how to generate them.
  • Documentation included
  • Short description in the Development section of NEWS.md

@rcabell rcabell mentioned this pull request Feb 1, 2022
6 tasks
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

Successfully merging this pull request may close these issues.