A passive scalar is a quantity that is transported by the fluid but does not alter the fluid's behavior such as a tracer dye. Athena++ is capable of solving the following equation (in conservation form) for the evolution of any number of passive scalar species: scalar conservation where scalar diffusion flux Similar to the hydrodynamic variables, solving this governing equation requires maintaining a dual representation of the passive scalar fields.

  • Conservative variables:
  • Primitive variables:

Variable floors are applied to these quantities during interface reconstruction and equation of state conversions to ensure that 1) the primitive r remains in [0, 1] and 2) the conservative s is consistent with r and the fluid density.

To configure the code to evolve one or more species of passive scalars, run the configure.py script with --nscalars=N. This will set the internal preprocessor macro NSCALARS to N. See the Configuring page for more details.

As mentioned within the Problem Generators page, if NSCALARS > 0, the required implementation of void MeshBlock::ProblemGenerator(ParameterInput *pin) must initialize the conservative formulation AthenaArray<Real> PassiveScalar::s of each type of passive scalar on every MeshBlock. The following code is an example created by modifying the function in src/pgen/slotted_cylinder.cpp:

void MeshBlock::ProblemGenerator(ParameterInput *pin) {
  AthenaArray<Real> vol(ncells1);
  Real d0 = 1.0;  // uniform fluid density across the mesh
  // initialize conserved variables
  for (int k=ks; k<=ke; k++) {
    for (int j=js; j<=je; j++) {
      pcoord->CellVolume(k, j, is, ie, vol);
      for (int i=is; i<=ie; i++) {
        // uniformly fill all scalars to have equal concentration
        constexpr int scalar_norm = NSCALARS > 0 ? NSCALARS : 1.0;
        if (NSCALARS > 0) {
          for (int n=0; n<NSCALARS; ++n) {
            pscalars->s(n,k,j,i) = d0*1.0/scalar_norm;
          }
        // ... initialize Hydro conserved variables
        }
      }
    }
  }

Another simple example of this initialization is provided in src/pgen/shock_tube.cpp.

Compatibility with other code features

  • Passive scalars are automatically compatible with all of the built-in Boundary Conditions and their associated flags. As with the hydrodynamic variables, the boundary conditions are applied to the cell-centered primitive passive scalar quantities (dimensionless concentrations) and the conservative passive scalar variables (specieis densities) are automatically calculated from those updated values. However, User-Defined Boundary Conditions are currently unsupported for NSCALARS > 0 since there is no AthenaArra<Real> &r parameter in the function signature. We are planning on extending this feature soon.
  • When NSCALARS > 0, the Outputs that specify either cons or prim variables will automatically include the conservative or primitive formulation of each passive scalar species, respectively. Restart Files for simulations with passive scalars will (and must!) contain the conserved s data across the mesh.
  • The treatment of passive scalars is also compatible with both Static Mesh Refinement (SMR) and Adaptive Mesh Refinement (AMR). For AMR,
  • Diffusion Processes are also supported for the passive scalars, and can be activated by setting a positive problem/nu_scalar_iso value in The Input File or when Overriding Input Parameters.

Example

> make clean; ./configure.py --prob=slotted_cylinder --eos=isothermal --nscalars=1 --nghost=4 -mpi -hdf5; make -j
> cd bin
> mpirun -n 8 ./athena -i ../inputs/hydro/athinput.slotted_cylinder2d_refined mesh/nx1=100 mesh/nx2=100 mesh/refinement=adaptive time/xorder=3 time/integrator=rk3

Figure 1: plot of the passive counter-clockwise advection of a 2D slotted cylinder scalar profile at t=0.4 using RK3+PPM with AMR. 2D slotted cylinder

Figure 2: same result as shown in Figure 1 but zoomed-in near the sharp discontinuities around the slot. The gas velocity vector field is overlaid in a constant color. 2D slotted cylinder zoomed

Clone this wiki locally