Description
When performing a pair of ON/OFF scans, the location of the OFF scan is typically specified as the location of the ON scan plus an offset (typically 3 degrees in our recent MeerKAT test scans). The RA and Dec values published must include this offset so that the RA and Dec values the metadata will refer to the actual RA and Dec location (in J2000 epoch) that the array was pointing towards.
The ON/OFF scans from the 2020-05-21 test session had equal values for RA and Dec. The offset was not included in the RA/Dec values for the OFF scan.