The following postStartHook will be injected in the fuse-sidecar to check the mount status.
lifecycle:
postStart:
exec:
command: [ "/bin/sh", "-c", "time /check-mount.sh >> /proc/1/fd/1" ]
However, the startup of the Container and the execution of the PostStartHook occur in parallel. it is possible that when the PostStartHook is executed, the PID 1 process inside the container has not completed its startup. This can lead to a failure in redirecting to /proc/1/fd/1 when the PostStartHook runs the check-mount script.
The relevant error log in Kubelet (1.31) is as follows:
PostStartHookError: Exec lifecycle hook ([bash -c time /check-mount.sh >> /proc/1/fd/1]) for Container "fluid-fuse-0" in Pod "" failed - error: command 'bash -c time /check-mount.sh >> /proc/1/fd/1' exited with 1: bash: /proc/1/fd/1: Permission denied