A doubt of QM/MM interface #5

@taipinghu

Description

@taipinghu

We can perform QM/pol-MM calculations using Gaussian for QM part calculation and Tinker for MM part calculation. I just have a doubt:
How does the MM part respond to the QM part for a self-consistent calculation? Or only self-consistent calculation of MM part is taken into account. I think the following processes must be taken into consideration:
(1)calculate QM part and get electron density;
(2)calculate MM part based on the QM electron density;
(3) loop for (1) and (2) in order to converge.
And can you provide a more detailed description about it in the Garleek interface? Thank you.