2.0.0-beta.3

Pre-release
Pre-release
Compare
Choose a tag to compare
@jisotalo jisotalo released this 10 Sep 18:55
· 69 commits to master since this release

[2.0.0-beta.3] - 10.09.2024

  • BREAKING: Renamed ReadWriteRawMultiCommand property writeData to value
  • Added warning event to listen for console warnings
  • Bugfix: writeRawByPath() didn't use the targetOpts parameter
  • Type ClientEvents renamed to AdsClientEvents
  • Added automatic deletion of stale subscriptions / unknown ADS notification handles
    • New setting: deleteUnknownSubscriptions (default: true)

Thank you Christian Rishøj for contribution!

[2.0.0-beta.2] - 26.08.2024

  • Changed subscribeSymbol() -> subscribeValue()
  • Bug fix: Fixing issue #144

[2.0.0-beta.1] - 24.08.2024

IMPORTANT: This is a major version update. There are lots of breaking changes!

Updating v1 -> v2 requires manual changes to your codebase!

See MIGRATION.md for all breaking changes and follow the instructions. This changelog does not have breaking changes listed for 2.0.0.

Changes

  • Everything rewritten in TypeScript
  • Everything is tested before releasing
  • Lots of optimizations
  • Lots of name changes
  • New methods: resetPlc(), readWriteRawMulti(), writeRawByPath(), readValueBySymbol(), writeValueBySymbol()
  • New setting disableCaching: disables all symbol and data type caching
  • Added optional targetOpts argument in all methods
    • Possible to provide different target address (AmsNetId and/or AdsPort) than specified in the settings
    • Caching is only available for the original target provided in settings
    • The same client can be used for many different targets at the same time
  • Added support for reading/writing INTERFACE data types
  • Added support for reading/writing empty FUNCTION_BLOCKs
  • Added support for reading/writing BIT data type
  • Writing a STRING or WSTRING value that is longer than the target data type causes the string to be truncated.
    • Previously the string end character was lost, which caused "never ending string" and <Value of the expression cannot be retrieved in PLC online view.
    • E.g. writing 85 bytes of string to STRING(80) variable
  • BOOL and BIT data values are now true if the value is anything else than 0
    • In TwinCAT, BOOL is true if the value is anything else than zero (see x_TO_BOOL)
    • Before, ads-client set the value to true only if value was true or 1, otherwise it was 0
  • writeControl() accepts also string values for adsState