Notifications
You must be signed in to change notification settings - Fork 330
Description
Hallo eBusD User,
meine Vaillant geoTherm KNX Anbindung funktioniert bis auf die einmal Speicherladung.
Fehlermeldung eBusD.log:
[knx debug] received unsubscribed write from fff2 to 1563, len 3
Mit „ebusctl w -c hwc load 1“ funktioniert es einwandfrei.
Hat jemand einen Tip für mich?
Danke,
Grüße aus Karlsruhe
Zur Info:
address 00: master #1
address 03: master #11
address 04: slave #25, ebusd, scanning
address 08: slave #11, scanned "MF=Vaillant;ID=EHP00;SW=0419;HW=7201", loaded "vaillant/08.ehp.csv"
address 10: master #2
address 15: slave #2, scanned "MF=Vaillant;ID=UIH00;SW=0374;HW=6901", loaded "vaillant/15.uih.csv"
address 23: slave, scanned "MF=Vaillant;ID=EHP00;SW=0419;HW=7201", loaded "vaillant/23.ehp.cc.csv"
address 25: slave, scanned "MF=Vaillant;ID=EHP00;SW=0419;HW=7201", loaded "vaillant/25.ehp.hwc.csv"
address 26: slave, scanned "MF=Vaillant;ID=EHP00;SW=0419;HW=7201"
address 31: master #8
address 50: slave, scanned "MF=Vaillant;ID=EHP00;SW=0419;HW=7201", loaded "vaillant/50.ehp.mc.csv"
address ff: master #25, ebusd
ebusctl find -w load
ehp PowerCutPreloading = 0
hwc load = on
mc load = no data stored
uih HwcLoadingTimeMax = no data stored
uih load = no data storeduih HwcLoadingTimeMax = no data stored