Skip to content

Releases: ku-cms/eLink_Instrumentation

Auto_EyeBERT_v2.0

26 Aug 20:41
1cdf327
Compare
Choose a tag to compare

Auto_EyeBERT_v2.0

  • Now supports Rev A and Rev B relay boards
  • New scripts for Rev B relay board
  • New area template, TXDIFFSWING setting, and 4-point DC calibration for Rev B relay board
  • For 4-pt DC calibration, ask user to accept or redo each measurement before continuing
  • Fix DMM problem: wait 100 ms before reading values
  • Use separate TCL create scan TCL files for Rev A and Rev B relay boards, which mitigates issues in switching relay boards, as the user does not have to edit this file.

See pull requests:

Auto_EyeBERT_v1.1

23 Jul 21:51
Compare
Choose a tag to compare

Auto_EyeBERT_v1.1

  • Update to template analysis: switch from template v2 to template v3

Auto_EyeBERT_v1.0

23 Jul 20:39
d50db06
Compare
Choose a tag to compare

Auto_EyeBERT_v1.0

  • Automated eye-bert and DC resistance measurements.
  • Using "Rev A" relay board.
  • The user inputs e-link number, type, and branch (among other things).
  • The python script runs on one e-link branch, all channels.