While discussing the available_output
test introduced in #453 with @klindsay28, I noted that output_for_gcm_registry
was a private component of the MARBL interface class but is needed in the driver. We both agree that it is undesirable to have something public solely for the purpose of calling it from the test suite, and brainstormed possible fixes.
One idea that we both like is to have a report_output_for_GCM()
function that contains all the logic of the stand-alone available_output
test and is also called from init()
-- it would be useful for the GCM to log what is (and is not) available, and this reduces duplicate code. Taking this a step further, the output from all the requested_*
tests could be generated from function calls and shared between the test suite and initialization. For example, this block of code from marbl_init_mod.F90
!--------------------------------------------------------------------
! Report what forcings are required from the driver
!--------------------------------------------------------------------
call marbl_status_log%log_header('MARBL-Required Forcing Fields', subname)
call marbl_status_log%log_noerror('Surface:', subname)
do i=1,size(surface_flux_forcings)
write(log_message, "(2A)") '* ', trim(surface_flux_forcings(i)%metadata%varname)
call marbl_status_log%log_noerror(log_message, subname)
end do
call marbl_status_log%log_noerror('', subname)
call marbl_status_log%log_noerror('Interior:', subname)
do i=1,size(interior_tendency_forcings)
write(log_message, "(2A)") '* ', trim(interior_tendency_forcings(i)%metadata%varname)
call marbl_status_log%log_noerror(log_message, subname)
end do
looks an awful lot like the code in the request_forcings
case in the stand-alone driver
! Log requested surface forcing fields
call driver_status_log%log_header('Requested surface forcing fields', subname)
do n=1,size(marbl_instances(1)%surface_flux_forcings)
write(log_message, "(I0, 5A)") n, '. ', &
trim(marbl_instances(1)%surface_flux_forcings(n)%metadata%varname), &
' (units: ', trim(marbl_instances(1)%surface_flux_forcings(n)%metadata%field_units),')'
call driver_status_log%log_noerror(log_message, subname)
end do
! Log requested interior forcing fields
call driver_status_log%log_header('Requested interior forcing fields', subname)
! Provide message if no itnerior tendency forcings are requested
if (size(marbl_instances(1)%interior_tendency_forcings) == 0) &
call driver_status_log%log_noerror('No forcing fields requested for interior_tendency_compute()!', subname)
do n=1,size(marbl_instances(1)%interior_tendency_forcings)
write(log_message, "(I0, 5A)") n, '. ', &
trim(marbl_instances(1)%interior_tendency_forcings(n)%metadata%varname), &
' (units: ', trim(marbl_instances(1)%interior_tendency_forcings(n)%metadata%field_units),')'
call driver_status_log%log_noerror(log_message, subname)
end do
although I updated the stand-alone test to include the forcing units and that is not reflected in the log output from initialization. Similarly, the output of requested_tracers
includes units while the initialization log just lists the tracer short names.